HOME
Back to Main Page
Introduction
Technical Features
How to install 1
How to install 2
INSTART Kits
Kits Techn. Data
2KW Starter Unit
Images of products
Accessories avail.

  

 

  How to install 2


REPHASING CAPACITOR
.

Since the ballst/lamp system is an inductive load, the circuit has a power factor of about 0.4-0.6 . Therefore it is convenient to add a phase capacitor, with appropriate value, connected in parallel to mains. The capacitor in H.R. systems has also the function to filter and block the ignition voltage peaks which could be transmitted towards mains, producing supply line noise and interferences. If a circuit with autotransformer is used, it is convenient to connect phase capacitor after the autotransformer, thus allowing the use of a smaller size one .

CONTROLS BEFORE SYSTEM STARTING.

bullet

 Follows correctly the schematics reported on ignitor label.

bullet

Check that the main supply is correct and within the operating range of ballast/ignitor.

bullet

Check the absence of any conductive foreign body close to the parts to which voltage is applied and particularly to HV cable.

STARTING TEST WITHOUT LAMP.

Test the system without installing the lamp. At mains switching on, verify that in no part of the luminaire or gearbox are visible sparks or arcings.
Test should be effected in a dark place.

STARTING WITH LAMP.

After lamp ignition, wait that system has reached the typical working condition. Then simulate a mains failure (switching off/on the main supply). If lamp doesn’t re-start, before replacing the ignitor or the ballast, verify wiring, fuses and that safety door switch operates correctly. 

SYSTEM OPERATING.

bullet

Avoid unnecessary lamp re-ignitions: too much hot re-starts can affect the lamp lifetime.

bullet

Check that lamp and system temperatures are within those specified by the Manufacturer.

bullet

Replace the lamp immediately after it is exhausted.

bullet

Do not operate with H.R. system in open circuit condition (without lamp installed): although ballast is projected to bear a condition of open circuit, this could affect the wiring and components insulation.

bullet

Before making any system repairs, make sure that mains is cut out.

bullet

For any installing or operating problem, please contact us immediately.

bullet

We do not assume any responsibility in case of wrong installation or connection.

 

 


HOME ] Back to Main Page ]